STAAD.Pro Help

Cold-formed Angle Shape Tables

The follow details are used for cold-formed angle shapes in standard database tables

Note: The required first two columns for all standard databases are RecNo and Name.
Note: For cold-formed sections, only equal leg angle shapes are supported (i.e., L1 = L2).

Table 1. Angle shape mandatory properties
Name Description Unit Column No.
L1 Depth in 3
L2 Width in 4
T Thickness in 5
Table 2. Angle shape optional properties
Name Description Unit Column No.
LIP Lip length length 6
RRAD Root radius (inner bend radius) length 7

Spreadsheet Data Examples

Table 3. Angle Section - English units
Name L1 L2 T RRAD LIP
(in) (in) (in) (in) (in)
4LS4x135 4 4 0.135 0.1875 0.5
Table 4. Angle Section - Metric units
Name L1 L2 T A LIP
(mm) (mm) (mm) (cm^2) (mm)
L60X2JB 60 60 2 2.95 20